Temp. range | -45℃~225℃ | -60℃~225℃ | -80℃~225℃ | -100℃~225℃ | -120℃~225℃ | |
Calefactio potentiae | 3.5kw | 3.5kw | 3.5kw | 4.5kw | 4.5kw | |
Facultatem refrigerandum | AT -45℃ | 2.5kw | ||||
AT -60℃ | 2KW | |||||
AT -80℃ | 1.5KW | |||||
AT -100℃ | 1.2KW | |||||
AT -120℃ | 1.2KW | |||||
Temp. Sagaciter | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | |
Temperatus conversionem tempore | -25℃ ad 150℃ circiter 10S 150℃to -25℃ | -45℃ ad 150℃ circiter 10S 150℃to -45℃ | -55℃ ad 150℃ circiter 10S 150℃to -55℃ | -70℃ ad 150℃ circiter 10S 150℃to -70℃ de 20s | -80℃ ad 150℃ circiter 11S 150℃to -80℃ de 20s | |
Air iudicium | Air filter <5um Oleum contentum in aere: < 0.1ppm Aeris temperies et humiditas: 5 ℃~ 32 ℃ 0 50% RH | |||||
Aeris pertractatio facultatem | 7m3/h 25m3/h pressus 5bar~7.6bar | |||||
Ratio pressura ostentationem | Pressura refrigerationis ratio efficitur a monstratorem pressura METIOR (princeps pressura et humilis pressura) | |||||
Controller | Siemens PLC, quamquam PID control algorithmus | |||||
temperatus imperium | Imperium temperatus exitus aeris | |||||
Programmable | 10 programmata programmari possunt, et unaquaeque programma cum 10 gradibus institui potest | |||||
communicationis protocol | Aer interface TCP / IP protocol | |||||
Aer interface TCP / IP protocol | Apparatus exitus temperatus, refrigerationis ratio condensationis temperatus, temperatus ambiens, temperatus compressor suctionis; refrigerandum aqua temperatus (aquam refrigerationem armorum habet) | |||||
Temperatus feedback | T-type temperatus sensorem | |||||
compressor | Taikang | Taikang | Taikang | Duling, Italy | Duling, Italy | |
evaporator | Sleeve genus calor exchanger | |||||
calefacientis | Ferrum LABIUM calefacientis | |||||
Refrigeration accessiones | Danfoss / Accessories Emerson (siccatio colum, separator olei, pressionis altae et humilis protector, valvae expansionis, valvae solenoidei) | |||||
operatio panel | Wuxi Guanya nativus 7-inch color tactus screen, temperatura curva ostentus et Praecedo notitia export | |||||
salus tutela | Habet sui diagnosis munus, phase series aperta phase protector, armarium onerare praesidium, alta intentione pressionis switch, Nullam nullam, scelerisque tutelam machinam et alia munia tutelae salutis. | |||||
Refrigerant | LNEYA mixtum refrigerandi | |||||
Externi velit caligarum | Opportuna traditio caligarum 1.8m DN32 ex velox iuncturae fibulae | |||||
Dimensio externa cm | 45*85*130 | 55*95*170 | 70*100*175 | 80*120*185 | 100* 150* 185 | |
Dimensio (aqua) cm | 45*85*130 | 45*85*130 | 55*95*170 | 70*100*175 | 80*120*185 | |
Genus aeris refrigeratum | Adhibet tubo aeneo et aluminio pinnae modo densationis et aeri incluso superioris speciei. Condensatio ventilabrum EBM fluxus axialis Germanici adoptat fan | |||||
W * aqua refrigeratum | Exemplar apud W est aqua refrigeratum | |||||
aqua refrigeratum condenser | Commutator caloris fistularis (Paris / Shen) | |||||
Aqua frigida in 25 | 0.6m3/h | 1.5m3/h | 2.6m3/h | 3.6m3/h | 7m3/h* | |
Potentiae copia: 380V, 50Hz | 4.5kw max | 6.8kw max | 9.2kw max | 12.5kw max | 16.5kw max | |
Potestas Supple | Nativus esse potest 460V 60Hz, 220V 60Hz tres phase | |||||
Testa materia | Plastic spraying of cold sheet involutus (vexillum color 7035). | |||||
Expansio caliditas | Caliditas ad + 300 |