• page_banner01

News

News

  • IP56X sand and dust test chamber correct operation guide:

    IP56X sand and dust test chamber correct operation guide:

    • Step 1: First, make sure the sand and dust test chamber is connected to the power supply and the power switch is in the off state. Then, place the items to be tested on the test bench for detection and testing. • Step 2: Set the parameters of the test chamber according to the test requirements....
    Read more
  • How to replace the dust in the sand and dust test chamber?

    How to replace the dust in the sand and dust test chamber?

    The sand and dust test chamber simulates the natural sandstorm environment through built-in dust, and tests the IP5X and IP6X dustproof performance of the product casing. During normal use, we will find that the talcum powder in the sand and dust test box is lumpy and damp. In this case, we need ...
    Read more
  • Small details of rain test chamber maintenance and maintenance

    Small details of rain test chamber maintenance and maintenance

    Although the rain test box has 9 waterproof levels, different rain test boxes are designed according to different IP waterproof levels. Because the rain test box is an instrument to test data accuracy, you must not be careless when doing maintenance and maintenance work, but be cautious.   T...
    Read more
  • Detailed classification of IP waterproof level:

    Detailed classification of IP waterproof level:

    The following waterproof levels refer to international applicable standards such as IEC60529, GB4208, GB/T10485-2007, DIN40050-9, ISO20653, ISO16750, etc.: 1. Scope: The scope of waterproof test covers the protection levels with the second characteristic number from 1 to 9, coded as IPX1 to IPX9K...
    Read more
  • Description of IP dust and water resistance levels

    Description of IP dust and water resistance levels

    In industrial production, especially for electronic and electrical products used outdoors, dust and water resistance are critical. This capability is usually evaluated by the enclosure protection level of automated instruments and equipment, also known as the IP code. Th...
    Read more
  • How to reduce composite material testing variability?

    How to reduce composite material testing variability?

    Have you ever encountered the following situations: Why did my sample test result fail? The test result data of the laboratory fluctuates? What should I do if the variability of the test results affects the product delivery? My test results do not meet the customer's req...
    Read more
  • Common Mistakes in Tensile Testing of Materials

    Common Mistakes in Tensile Testing of Materials

    As an important part of material mechanical properties testing, tensile testing plays an important role in industrial manufacturing, material research and development, etc. However, some common errors will have a huge impact on the accuracy of test results. Have you noticed these details? 1.The f...
    Read more
  • Understanding the Dimension Measurement of Specimens in Material Mechanics Testing

    In daily testing, in addition to the accuracy parameters of the equipment itself, have you ever considered the impact of sample size measurement on the test results? This article will combine standards and specific cases to give some suggestions on the size measurement of some common materials. ...
    Read more
  • What should I do if I encounter an emergency during testing in the high and low temperature test chamber?

    What should I do if I encounter an emergency during testing in the high and low temperature test chamber?

    The treatment of interruption of high and low temperature test chamber is clearly stipulated in GJB 150, which divides the test interruption into three situations, namely, interruption within the tolerance range, interruption under test conditions and interruption under ...
    Read more
  • Eight ways to extend the service life of constant temperature and humidity test chamber

    Eight ways to extend the service life of constant temperature and humidity test chamber

    1. The ground around and at the bottom of the machine should be kept clean at all times, because the condenser will absorb fine dust on the heat sink; 2. The internal impurities (objects) of the machine should be removed before operation; the laboratory should be cleaned...
    Read more
  • LCD liquid crystal display temperature and humidity test specifications and test conditions

    LCD liquid crystal display temperature and humidity test specifications and test conditions

    The basic principle is to seal the liquid crystal in a glass box, and then apply electrodes to cause it to produce hot and cold changes, thereby affecting its light transmittance to achieve a bright and dim effect. Currently, common liquid crystal display devices include Twisted Nematic (TN), Sup...
    Read more
  • Test standards and technical indicators

    Test standards and technical indicators

    Test standards and technical indicators of temperature and humidity cycle chamber: The humidity cycle box is suitable for safety performance testing of electronic components, providing reliability testing, product screening testing, etc. At the same time, through this test, the reliability of the...
    Read more