Model |
UP-LED500 |
UP-LED800 |
UP-LED1000 |
UP-1500 |
|
Inner size(mm) |
500x500x600 |
1000x800x1000 |
1000x1000x1000 |
1000x1000x1500 |
|
Outer(mm) |
1450X1400X2100 |
1550X1600X2250 |
1550X1600X2250 |
1950X1750X2850 |
|
Performance |
Temp Range |
0℃/-20℃/-40℃/-70℃~+100℃/+150℃/+180℃ |
|||
Temp uniformity |
≤2℃ |
||||
Temp deviation |
±2℃ |
||||
Tempfluctuation |
≤1℃(≤±0.5℃, refer to GB/T5170-1996) |
||||
Heating time |
+20℃~+100℃about30m/+20℃~+150℃about45minites |
||||
Cooling time |
+20℃~-20℃about 40m / 从+20℃~-40℃about 60m/ 从+20℃~-70℃about 70m |
||||
Humidity range |
20~98%RH |
||||
Humidity deviation |
±3%(75%RH below), ±5%(75%RH above) |
||||
Temp Controller |
Chinese and English color touch screen + PLC controller |
||||
Low temp system adaptability |
Meet the compressor automatic operation in the full temperature range |
||||
Equipment operation mode |
Fixed value operation, program operation |
||||
Cooling System |
Imported fully enclosed compressor |
Imported fully enclosed compressor |
|||
Air-cooled |
Air-cooled |
||||
Humidification water |
Distilled or deionized water |
||||
Safety protection measures |
Leakage, short circuit, over temperature, water shortage, motor overheating, compressor over pressure, overload, over current |
||||
Power -40°C (KW) |
9.5KW |
11.5KW |
12.5KW |
16KW |
|
Standard device |
Sample shelf (two sets), observation window, lighting lamp, cable hole (Ø50 one), with casters |
||||
power supply |
AC380V 50Hz three-phase four-wire + ground wire |
||||
Material |
Shell material |
Electrostatic spraying of cold-rolled steel plate (SETH standard color) |
|||
Inner wall material |
SUS304 stainless steel plate |
||||
Insulation Materials |
Rigid polyurethane foam |
◆ Equipped with test racks for semi-finished LED products;
◆ The large window can achieve the purpose of online test and observation more effectively;
◆ Meet the power-on and bias test in the LED test process, equipped with integration capabilities and communication commands (Labview, VB, VC, C++), equipped with 4. standby power supply load on-off control system;
◆ It is very reliable to control the stability of the product's super-large load heat in the high temperature and high humidity, low-temperature storage, and environmental cycle control of Seth;
◆ Effectively solve the problem of preventing condensation and water dew;
◆ Equipped with RS232 data connection port, USB data storage, and download function;
◆ Effectively achieve low humidity 60°C (40°C)/20%RH efficiency;
◆ Effectively solve the problem of preventing condensation and water dew;
1. GB/T10589-1989 low-temperature test chamber technical conditions; 2. GB/T10586-1989 damp heat test chamber technical conditions;
3. GB/T10592-1989 high and low-temperature test chamber technical conditions; 4. GB2423.1-89 low-temperature test Aa, Ab;
5. GB2423.3-93 (IEC68-2-3) constant damp heat test Ca; 6. MIL-STD810D method 502.2;
7. GB/T2423.4-93 (MIL-STD810) method 507.2 procedure 3; 8. GJB150.9-8 damp heat test;
9.GB2423.34-86, MIL-STD883C method 1004.2 temperature and humidity combined cycle test;
10.IEC68-2-1 test A; 11.IEC68-2-2 test B high and low temperature alternating; 12.IEC68-2-14 test N;
IEC 61215 Solar Module Reliability Test
IEEE 1513 temperature cycle test & damp freezing test & damp heat test
UL1703 Flat Panel Solar Module Safety Certification Standard
IEC 61646 Thin Film Solar Photovoltaic Module Test Standard
IEC61730 Solar cell system safety-structure and test requirements
IEC62108 Concentrating Solar Receiver and Parts Evaluation Standard