• ikhasi_isibhengezo01

Izindaba

Ukuhlukaniswa okuningiliziwe kwezinga le-IP elingangeni manzi:

Lawa mazinga alandelayo angangeni manzi abhekisele kumazinga asebenzayo wamazwe ngamazwe afana ne-IEC60529, GB4208, GB/T10485-2007, DIN40050-9, ISO20653, ISO16750, njll.:

1. Ububanzi:Ububanzi bokuhlola okungenamanzi buhlanganisa amaleveli okuvikela ngenombolo yesibili yesici ukusuka ku-1 ukuya ku-9, efakwe ikhodi njenge-IPX1 ukuya ku-IPX9K.

2. Okuqukethwe kwamazinga ahlukahlukene okuhlolwa okungenamanzi:Izinga lokuvikelwa kwe-IP lizinga lamazwe ngamazwe elisetshenziselwa ukuhlola amandla okuvikela ezindlu zezinto zikagesi ezintweni eziqinile kanye nokungena kwamanzi. Izinga ngalinye linezindlela zokuhlola ezihambisanayo nezimo zokuqinisekisa ukuthi okokusebenza kungafinyelela umphumela wokuvikela olindelwe ekusetshenzisweni kwangempela. I-Yuexin Test Manufacturer iyinhlangano yokuhlola yenkampani yangaphandle eneziqu ze-CMA ne-CNAS, egxile ekuhlinzekeni ngezinsizakalo zokuhlola ukusebenza kwe-IP ezingangeni manzi nezingangeni uthuli, esiza amakhasimende ukuthi athole ukuqonda okujulile ngokusebenza kwemikhiqizo yawo, futhi angakhipha imibiko yokuhlola nge-CNAS. kanye nezimpawu ze-CMA.

 

Okulandelayo incazelo enemininingwane yezindlela zokuhlola zamaleveli e-IPX ahlukene:

• IPX1: Ukuhlolwa kokuconsa okuqondile:
Izinto zokuhlola: idivayisi yokuhlola ukuconsa:
Ukubekwa kwesampula: Isampula libekwe kuthebula lesampula elijikelezayo endaweni yokusebenza evamile, futhi ibanga ukusuka phezulu ukuya embobeni yokuconsa alikho ngaphezu kuka-200mm.
Izimo zokuhlola: Ivolumu yokuconsa ingu-1.0+0.5mm/min, futhi ihlala imizuzu eyi-10.
Imbobo yenaliti yokudonsa: 0.4mm.

• IPX2: 15° ukuhlolwa kokuconsa:
Imishini yokuhlola: idivayisi yokuhlola i-drip.
Ukubekwa kwesampula: Isampula sitsheke ngo-15°, futhi ibanga ukusuka phezulu ukuya embobeni yokuconsa alikho ngaphezu kuka-200mm. Ngemva kokuhlolwa ngakunye, shintshela kolunye uhlangothi, ingqikithi izikhathi ezine.
Izimo zokuhlola: Ivolumu ye-drip ingu-3.0+0.5mm/min, futhi ihlala imizuzu engu-4×2.5, ingqikithi yemizuzu eyi-10.
Imbobo yenaliti yokudonsa: 0.4mm.
IPX3: Ukuhlola isifutho samanzi sepayipi lokushwibeka kwemvula:
Imishini yokuhlola: Ipayipi lokujikijela isifutho samanzi kanye nokuhlolwa kwe-splash.
Ukubekwa kwesampula: Ubude betafula lesampula busendaweni yobubanzi bepayipi lokushwiba, futhi ibanga ukusuka phezulu ukuya embobeni yesampula yesifutho samanzi alikho ngaphezu kuka-200mm.
Izimo zokuhlola: Izinga lokugeleza kwamanzi libalwa ngokwenani lezimbobo zokufafaza zamanzi zepayipi lokushwibeka, 0.07 L/min imbobo ngayinye, ipayipi lokushwiba lishwibeka ngo-60 ° nhlangothi zombili zomugqa oqondile, ukushwibeka ngakunye cishe imizuzwana emi-4, futhi ihlala imizuzu eyi-10. Ngemuva kwemizuzu emi-5 yokuhlola, isampula lizungeza u-90°.
Ingcindezi yokuhlola: 400kPa.
Ukubekwa kwesampula: Ibanga elihambisanayo ukusuka phezulu ukuya embotsheni yesifutho samanzi yombhobho ophathwa ngesandla liphakathi kuka-300mm no-500mm.
Izimo zokuhlola: Izinga lokugeleza kwamanzi ngu-10L/min.
Ububanzi bembobo yesifutho samanzi: 0.4mm.

• IPX4: Ukuhlolwa kwe-Splash:
Ukuhlolwa kokuchaphazeka kwepayipi: Izinto zokuhlola nokubekwa kwesampula: Kuyafana ne-IPX3.
Izimo zokuhlola: Izinga lokugeleza kwamanzi libalwa ngokwenani lezimbobo zesifutho samanzi zepayipi lokushwibeka, 0.07L/min imbobo ngayinye, futhi indawo yesifutho samanzi amanzi afuthwe emigodini yesifutho samanzi ku-90° arc kuzo zombili. izinhlangothi zephoyinti elimaphakathi lepayipi lokushwiba ukuya kusampula. Ipayipi lokushwiba lishwibeka ngo-180° nhlangothi zombili zomugqa oqondile, futhi ukushwibeka ngakunye kuthatha imizuzwana eyi-12 imizuzu eyi-10.
Ukubekwa kwesampula: Ibanga elihambisanayo ukusuka phezulu ukuya embotsheni yesifutho samanzi yombhobho ophathwa ngesandla liphakathi kuka-300mm no-500mm.
Izimo zokuhlola: Izinga lokugeleza kwamanzi ngu-10L/min, futhi isikhathi sokuhlola sibalwa ngokuya ngendawo engaphezulu yegobolondo langaphandle lesampula okufanele lihlolwe, iminithi elingu-1 imitha yesikwele, kanye nobuncane bemizuzu emi-5.
Ububanzi bembobo yesifutho samanzi: 0.4mm.

• IPX4K: Ukuhlolwa kwemvula yepayipi elicindezelweyo:
Izinto zokuhlola nokubekwa kwesampula: Kuyafana ne-IPX3.
Izimo zokuhlola: Izinga lokugeleza kwamanzi libalwa ngokwenani lezimbobo zesifutho samanzi zepayipi lokushwibeka, 0.6±0.5 L/min imbobo ngayinye, futhi indawo yesifutho samanzi amanzi afuthwe emigodini yesifutho samanzi ku-90° arc. ezinhlangothini zombili zephoyinti eliphakathi lepayipi lokushwiba. Ipayipi lokushwiba lishwibeka ngo-180° nhlangothi zombili zomugqa oqondile, ukushwibeka ngakunye kuthatha imizuzwana eyi-12, futhi kuthatha imizuzu eyi-10. Ngemuva kwemizuzu emi-5 yokuhlola, isampula lizungeza u-90°.
Ingcindezi yokuhlola: 400kPa.

• IPX3/4: Ukuhlola isifutho samanzi eshawa ephathwa ngesandla:
Imishini yokuhlola: Isifutho samanzi esiphathwa ngesandla kanye nedivayisi yokuhlola i-splash.
Izimo zokuhlola: Izinga lokugeleza kwamanzi ngu-10L/min, futhi isikhathi sokuhlola sibalwa ngokuya ngendawo engaphezulu yegobolondo lesampula elizohlolwa, iminithi elingu-1 imitha yesikwele, kanye nobuncane bemizuzu emi-5.
Ukubekwa kwesampula: Ibanga elihambisanayo lendawo yokufafaza amanzi yesifafazi esiphathwa ngesandla liphakathi kuka-300mm no-500mm.
Inani lemigodi yokufutha amanzi: 121 imigodi yokufutha amanzi.
Ububanzi bembobo yesifutho samanzi: 0.5mm.
Impahla ye-nozzle: yenziwe ngethusi.

• IPX5: Ukuhlolwa kwesifutho samanzi:
Imishini yokuhlola: Ububanzi bangaphakathi bomlomo wesifutho samanzi bomlomo ngu-6.3mm.
Izimo zokuhlola: Ibanga eliphakathi kwesampula nobhobho lwesifutho samanzi lingamamitha angu-2.5 ~ 3, izinga lokugeleza kwamanzi ngu-12.5L/min, futhi isikhathi sokuhlola sibalwa ngokwendawo yegobolondo elingaphandle lesampula ngaphansi. ukuhlolwa, iminithi elingu-1 imitha yesikwele, kanye nemizuzu emi-3 ubuncane.

• IPX6: Ukuhlolwa okuqinile kwesifutho samanzi:
Imishini yokuhlola: Ububanzi bangaphakathi bomlomo wesifutho samanzi bombobho ngu-12.5mm.
Izimo zokuhlola: Ibanga eliphakathi kwesampula nombobho wesifutho samanzi lingamamitha angu-2.5 ~ 3, izinga lokugeleza kwamanzi liyi-100L/min, futhi isikhathi sokuhlola sibalwa ngokwendawo yegobolondo elingaphandle lesampula ngaphansi kokuhlolwa. , iminithi elingu-1 imitha yesikwele, kanye nemizuzu emi-3 ubuncane.

• IPX7: Ukuhlolwa kwamanzi okucwiliswa kwesikhashana:
Imishini yokuhlola: ithangi lokucwiliswa.
Izimo zokuhlola: Ibanga ukusuka phansi kwesampula ukuya endaweni yamanzi okungenani liyimitha elingu-1, futhi ibanga ukusuka phezulu ukuya endaweni yamanzi okungenani lingamamitha angu-0.15, futhi lihlala imizuzu engu-30.

• IPX8: Ukuhlolwa kwe-diving okuqhubekayo:
Izimo zokuhlola nesikhathi: okuvunyelenwe ngazo yizinkampani ezinikezelayo nezifunayo, ubukhali kufanele bube phezulu kune-IPX7.

• IPX9K: Izinga lokushisa eliphezulu/ukuhlolwa kwejethi yomfutho ophezulu:
Imishini yokuhlola: Ububanzi bangaphakathi bombhobho ngu-12.5mm.
Izimo zokuhlola: I-engeli yokufafaza kwamanzi 0°, 30°, 60°, 90°, 4 izimbobo zokufafaza amanzi, isampula isivinini 5 ±1r.pm, ibanga 100~150mm, imizuzwana 30 endaweni ngayinye, ukugeleza izinga 14~16 L/ min, ingcindezi yesifutho samanzi 8000 ~ 10000kPa, izinga lokushisa lamanzi 80±5℃.
Isikhathi sokuhlola: imizuzwana engama-30 endaweni ngayinye × 4, isamba samasekhondi angu-120.

Ukuhlukaniswa okuningiliziwe kwezinga le-IP elingangeni manzi


Isikhathi sokuthumela: Nov-15-2024